Sign In | Join Free | My lightneasy.org |
|
Brand Name : Daxian
Model Number : DX8427
Certification : IEC60587, ASTMD2303
Place of Origin : China
MOQ : one set
Price : Negotiation
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 10 sets per month
Delivery Time : 5-8 work days
Packaging Details : Wooden case
Model No. : DX8427
Product name : Tracking And Erosion Testing Equipment
Material : Stainless steel
Dimensions : 1350L* 750W* 1800H (mm)
Power supply : 6000W
Weight : 300kg
High Voltage Tracking Testing Equipment
Application:
It is applicable to the test of electric and electronic products, household appliances and their materials for resistance to electric trace and corrosion. Under the power frequency (48Hz - 62Hz) or the corresponding DC voltage, liquid pollutants and inclined samples are used to evaluate the resistance to electric trace and corrosion of electrical insulation materials used under severe environmental conditions through the measurement of resistance to electric trace and corrosion.
Sample preparation:
① The sample shall be processed into flakes with a thickness of 6mm and a size of 50 × 120mm, and the electrode mounting hole is drilled, and a reference mark line is made at 45mm of the lower edge of the sample.
② Clean the sample with distilled water or deionized water to make its surface free of any dirt. If the sample surface is smooth, it should be polished slightly. The specific method is to polish the sample with 1500#.
Standards:
IEC60587, ASTMD2303.
Technical parameters:
Dimensions | 1350L* 750W* 1800H (mm) |
Working room volume | 800L *750W* 850H (mm) |
Electrode | 0.5mm thick ,material: stainless steel |
Test voltage | AC 0v-6000v stepless adjustable DC 0v-8400v stepless adjustable |
Power supply | 6000W |
Liquid flow range | 0.016-1.5ml/min can be set arbitrarily |
Dropping accuracy | 0.5% |
Test time | 0-10 hours can be set arbitrarily |
Configuration of contaminated liquid:
① . Concentration requirements for contaminated solution: use distilled water to prepare a mixed solution of (0.1 ± 0.002)% analytical pure NH4Cl (ammonia chloride) and (0.02 ± 0.002)% isooctyl phenoxy Polyethoxyethanol non-ionic wetting agent.
② . Preparation method of contaminated solution: add 2000ml distilled water to the measuring cup, weigh 2G of NH4Cl analytical pure solid and 0.4g of isooctyl phenoxy Polyethoxyethanol with a balance, add them to the distilled water, and stir them evenly with a glass rod.
Welcome to visit our factory for sightseeing !
Supplier Company Name | Daxian Instrument Equipment CO.,Limited |
Company Address | Changlian Industrial Building, 168 Zhenan West Road, Xiabian Community, Chang'an Town, Dongguan, Guang Dong, China |
Contact Person | Sophia Su |
Mobile Number | 86-13266221899 |
Telephone Number | 86-0769-82759287 |
![]() |
IEC 60587 Insulating Materials Erosion Testing Machine High Voltage Tracking Images |